8: Line and Tunnel Settings
EDS1100/2100 User Guide 54
3. Click Submit.
Connect Mode
Connect Mode defines how the EDS1100/2100 makes an outgoing connection. For Connect Mode
to function, it must be enabled, have a remote station configured, and a remote port configured
(TCP or UDP). When enabled, Connect Mode is always on.
Enter the remote station as an IP address or DNS name. The EDS will not make a connection
unless it can resolve the address. For DNS names, after 4 hours of an active connection, the EDS
will re-evaluate the address. If it is a different address, it will close the connection.
Connect Mode supports the following protocols:
TCP
AES encryption over TCP and UDP
SSH (the EDS1100/2100 is the SSH client)
SSL
Local Port Enter the port number for use as the local port. The defaults are port 10001
for Tunnel 1 and port 10002 for Tunnel 2.
Protocol Select the protocol type for use with Accept Mode. The default protocol is
TCP. If you select TCP AES you will need to configure the AES keys.
TCP Keep Alive Enter the time, in seconds, the EDS1100/2100 waits during a silent
connection before checking if the currently connected network device is still
on the network. If the unit then gets no response after 8 attempts, it drops that
connection.
Flush Serial Data Select Enabled to flush the serial data buffer on a new connection.
Block Serial Data Select On to block, or not tunnel, serial data transmitted to the EDS1100/
2100.
Block Network Data Select On to block, or not tunnel, network data transmitted to the EDS1100/
2100.
Password Enter a password that clients must send to the EDS1100/2100 within 30
seconds from opening a network connection to enable data transmission.
The password can have up to 31 characters and must contain only
alphanumeric characters and punctuation. When set, the password sent to
the EDS1100/2100 must be terminated with one of the following: (a) 0x0A
(LF), (b) 0x00, (c) 0x0D 0x0A (CR LF), or (d) 0x0D 0x00.
Email on Connect Select whether the EDS1100/2100 sends an email when a connection is
made. Select None if you do not want to send an email. Otherwise, select the
Email profile to use for sending.
Email on Disconnect Select whether the EDS1100/2100 sends an email when a connection is
closed. Select None if you do not want to send an email. Otherwise, select
the Email profile to use for sending.
CP Output Identifies a CP or CP Group whose value should change when a connection
is established and dropped.
Table 8-15 Tunnel Accept Mode Fields (continued)