SCSxx05/SCSxx20 User Guide 4: Configuration
4-12
7. Enter the desired log file size in bytes (2048 = 2K). The default is 2048 bytes.
The amount of available memory limits the maximum size of the log file.
8. Press Enter. the Device Logging Parameters menu returns with Syslog Port
Logging, selected.
Syslog Logging by Port
Next, you configure the following syslog options for the same port(s):
Enable/Disable (default is disabled)
Set Syslog Facility (user, local0, local1, local2, etc....local7)
Set Syslog Level (Emergency, Alert, Critical, Error, Warning, Notice, Info,
Debug)
1. With Syslog Port Logging selected, press Enter. The syslog flag prompt
displays.
2. Select to Enable or Disable (default) syslogging for the port(s), and press
Enter. The syslog facility prompt displays.
3. From the list, select the syslog facility to use for the port(s) and press Enter.
The set syslog level prompt displays.
4. From the list, select the syslog alert level for the port(s). The levels are, from
the top down, most severe to least severe. They classify the importance of
each connected server within your configuration.
5. Press Enter. The Device Logging Parameters menu returns with Email
Logging Port selected.
Email Logging
Email Logging (Email Notification) sends an email message to pre-defined email
addresses when 'alert' criteria have been met. Data received on the SCS device
port(s) trigger the alert. The default is disabled, although some preset values are
entered for the timers.
Email logging provides the following options for a port or group of ports:
Enable/disable (default is disabled)
Alarm byte count (count the number of characters to trigger an alarm)
Alarm timer (how long to capture data after byte count trigger)
Alarm ignore timer (how long, after byte count trigger, to ignore additional
alarms)
Email subject line (put in a message header to be read in the email
subject)
“Send To” email address
“cc:” to email address
1. With Email Logging Port selected, press Enter. The email flag prompt
displays.
2. Select Enable or Disable (default). If enabled, the email flag triggers an
email message to be sent to the defined recipients when the alert condition
has been met. Press Enter. The alarm byte counter prompt displays.