Lantronix MSS4 Guía de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 81
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
MSS User Guide 2: Installation
2-10
MSS4 Specifications
Power (power cube adaptor)
Adapter:
Input: 100-240 VAC US
Output: 12 VDC
Current: 1.5A @ 12VDC
MSS4 power input range: 9-30VDC
Temperature
Note: Rapid temperature changes may affect operation. Do not operate near heating or
cooling devices or areas that open to the outdoors.
Operating range: 5° to 50° C (41° to 122° F)
Storage range: 40° to 66° C (-40° to 151° F)
Max. temp change: 20° C (36° F) per hour
Humidity
Operating range: 10% to 90% non-condensing
40% to 60% recommended
Storage range: 10% to 90% non-condensing
Altitude
Note: For operations above 2.4 km (8,000 ft), decrease the operating temperature rating
by 1.8°C for each 1,000 m (1°F for each 1,000 ft).
Operating 2.4 km (8,000 ft)
Storage 9.1 km (30,000 ft)
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 80 81

Comentarios a estos manuales

Sin comentarios