UDS10/UDS100 User Guide Configuring the UDS Using Telnet or the Serial Port
23
Figure 5-2. Setup Mode
3. Select an option on the Change Setup menu by entering the number of the
option in the Your choice ? prompt and pressing Enter.
4. To enter a value for a parameter, type the value and press Enter. To confirm a
current value, just press Enter.
5. When you are finished, save the new configurations (option 9). The unit reboots.
Using the Serial Port
For local configuration, connect a terminal or a PC running a terminal emulation
program to the unit’s serial port (channel 1). Configure the terminal (or emulation) for
9600 baud, 8-bit, no parity, one stop bit, and no flow control.
1. Cycle the unit’s power (power off and back on). After power-up, the self-test
begins and the diagnostic and status LEDs start blinking.